HomeCalculatorsCylinder Oil Feed Rate - MAN ACC

Cylinder Oil Feed Rate - MAN ACC

MAN Anti-Corrosion Control feed-rate formula: 0.26 g/kWh × %S × BN70/BN_actual, minimum 0.6 g/kWh.

LubricationMAN
Feed rate
22.75g/kWh
Hourly consumption
273.00kg/h

Formula, assumptions, and limits

MAN Service Letter SL2014-593 - Anti-Corrosion Control formula. S in % m/m (NOT fraction). BN70 is the reference base number. Higher-S fuel needs more feed; higher-BN oil needs less.

Symbol legend

SymbolMeaningUnitSource
Fuel sulphur% m/mBDN
Cylinder oil base numbermg KOH/goil data
Engine powerkWload