ShipCalculators.com

Cylinder Oil Feed Rate - MAN ACC

Contents

Live calculator

MAN Anti-Corrosion Control feed-rate formula: 0.26 g/kWh × %S × BN70/BN_actual, minimum 0.6 g/kWh.

Formula

$$ \dot m_\text{cyl} = \max\!\left(0.6, \; 0.26 \cdot S \cdot \frac{70}{BN}\right) $$

Symbol legend

SymbolMeaningUnitSource
$S$Fuel sulphur% m/mBDN
$BN$Cylinder oil base numbermg KOH/goil data
$P$Engine powerkWload

Sources

  • MAN Service Letter SL2014-593.