HomeCalculatorsCross-Flooding Equalisation Time

Cross-Flooding Equalisation Time

Time to equalise an asymmetrically flooded tank pair through a cross-flooding duct - must be ≤ 10 min per MSC.245(83) / MSC.362(92).

Damage stability
Duct discharge
1.302m³/s
Equalisation time
3.84min
MSC.245(83) compliance
Compliant (≤ 10 min)

Formula, assumptions, and limits

$$\dot V = C_d \cdot A \cdot \sqrt{2 g h}, \quad t = \frac{V}{\dot V}$$

Simplified - actual calculation integrates as head falls. MSC.245(83) / MSC.362(92) method uses step-wise integration for transient-stage evaluation. Target ≤ 10 min final + transient-stage heel checks.

Symbol legend

SymbolMeaningUnitSource
$V$Flood-volume to transferlayout
$A$Duct cross-sectionarrangement
$h$Head differentialminitial heel × tank geometry
$C_d$Discharge coefficient - duct design

Spotted an error in this calculation? . We acknowledge editorial corrections within two working days.