Starting-air compressor sizing per SOLAS II-1 Reg. 32 - 12 consecutive starts in 1 h for reversing engine without reducer.
Formula
$$ \dot V = 2 \cdot V_{req} / t $$
Symbol legend
| Symbol | Meaning | Unit | Source |
|---|---|---|---|
| $V_req$ | Total air for starts | Nm³ | maker data |
Sources
- SOLAS II-1 Reg. 32.