ShipCalculators.com

Fresh-Water & Dock-Water Allowance

Contents

Live calculator

Fresh-Water Allowance (FWA) and Dock-Water Allowance (DWA) per Load Line Convention - the standard loaded-draft correction when crossing densities.

Formula

$$ FWA = \frac{\Delta}{4 \cdot TPC}, \quad DWA = FWA \cdot \frac{1025 - \rho_{dock}}{25} $$

Symbol legend

SymbolMeaningUnitSource
$\Delta$Summer displacementtload-line certificate
$TPC$Tonnes per cm immersion (SW)t/cmhydrostatic tables
$\rho_{dock}$Dock-water densitykg/m³hydrometer

Sources

  • Load Line Convention 1966/1988.