Lifeboat-falls load-test compliance - 1.1 × lifeboat + full complement, performed at 5-yearly interval per LSA Code / MSC.402(96).
Formula
$$ L_{test} = 1.1 \cdot (m_{LB} + N_{pax} \cdot m_{pax}) $$
Symbol legend
| Symbol | Meaning | Unit | Source |
|---|---|---|---|
| $m_{LB}$ | Lifeboat light mass | kg | lifeboat cert |
| $N_{pax}$ | Rated complement | pax | LSA cert |
Sources
- MSC.402(96) / LSA Code.