ShipCalculators.com

EEBD Duration - SOLAS II-2 Check

Contents

Live calculator

Check Emergency Escape Breathing Device (EEBD) service duration against SOLAS II-2 Reg. 13.4 minimum 10 min capacity at moderate activity.

Formula

$$ t = \frac{V_c \cdot p}{\dot V} $$

Symbol legend

SymbolMeaningUnitSource
$V_c$Cylinder volumeLmaker data
$p$Cylinder pressurebargauge
$\dot V$Consumption rateL/minactivity level

Sources

  • SOLAS II-2 Reg. 13.4.
  • ISO 23269-1.