ShipCalculators.com

Form Factor (Prohaska)

Contents

Live calculator

Three-dimensional extrapolation form factor (1+k) derived from low-Fn resistance data - the ITTC-78 correction that separates frictional from residual resistance.

Formula

$$ 1 + k = 0.93 + 0.4871 \cdot (B/L)^{1.07} \cdot (T/L)^{0.46} \cdot (1 + C_B)^{0.36} $$

Symbol legend

SymbolMeaningUnitSource
$C_B$Block coefficient-hydrostatics
$B/L$Beam-to-length ratio-particulars
$T/L$Draft-to-length ratio-particulars
$1 + k$Form factor-result

Sources

  • Prohaska (1966) - Form factor for ship extrapolation.
  • ITTC 7.5-02-02-01 Resistance Test.