Time for a self-priming centrifugal pump to evacuate the suction line to a specified vacuum.

Formula

$$ t = \frac{V_\text{line}}{\dot V_\text{air}} \cdot (1 + \text{margin}) $$

Symbol legend

SymbolMeaningUnitSource
$V_\text{line}$Volume to evacuateLpipe geometry
$\dot V_\text{air}$Pump air-handling capacityL/minpump data sheet

Sources

  • SOLAS II-2 FSS Ch.12.