Check cargo-tank venting outlet velocity - SOLAS II-2 Reg. 11.6 requires ≥ 30 m/s from P/V outlet to disperse vapour.
Formula
$$ v = Q / A \geq 30,m/s $$
Symbol legend
| Symbol | Meaning | Unit | Source |
|---|---|---|---|
| $Q$ | Venting flow rate | m³/s | loading rate |
| $A$ | Outlet cross-section | m² | venting design |
Sources
- SOLAS II-2 Reg. 11.6.