Ship-to-ship LNG bunker transfer time given bunker volume and max pump rate - basis for operational planning and WTW compliance analytics.
Formula
$$ t_{total} = \frac{V}{\dot V} \cdot 60 + t_{bridge} $$
Symbol legend
| Symbol | Meaning | Unit | Source |
|---|---|---|---|
| $V$ | LNG volume to transfer | m³ | bunker plan |
| $\dot V$ | Transfer rate | m³/h | pump / line capacity |
Sources
- SGMF Bunker Practice Guide.