ShipCalculators.com

Oil Mist Detector Trip (IACS UR M10)

Contents

Live calculator

Crankcase oil-mist concentration trip at 2.5 mg/L per IACS UR M10 on engines ≥ 2250 kW or cylinder bore ≥ 300 mm.

Formula

$$ \text{Trip} \text{ if } c_\text{mist} > 2.5 \text{ mg/L} $$

Symbol legend

SymbolMeaningUnitSource
$c_\text{mist}$Oil-mist concentration in crankcasemg/LOMD sensor

Sources

  • IACS UR M10.