ShipCalculators.com

IACS UR A2 - Emergency Towing SWL

Contents

Live calculator

Safe working load (SWL) of emergency towing arrangement fittings per IACS UR A2 - bollard and chock sized to at least 1.25 × expected towline break load.

Formula

$$ \text{SWL}_{fitting} \geq 1.25 \cdot BL_{line} $$

Symbol legend

SymbolMeaningUnitSource
$DWT$Deadweightdwttonnage certificate
$BL$Towline breaking strengthkNUR A2 Table
$SWL$Safe working loadkNIACS UR A1/A2

Sources

  • IACS UR A2.