ShipCalculators.com

Hydraulic Accumulator - Gas Pre-charge Sizing

Contents

Live calculator

Accumulator pre-charge pressure and required volume - critical for surge suppression in deck-machinery hydraulic systems.

Formula

$$ V_0 = \frac{\Delta V}{\left(\frac{p_0}{p_1}\right)^{1/n} - \left(\frac{p_0}{p_2}\right)^{1/n}} $$

Symbol legend

SymbolMeaningUnitSource
$p_0$Gas pre-charge pressurebarmaker guideline
$p_1, p_2$Min / max working pressurebarsystem design

Sources

  • Bosch Rexroth Accumulator Handbook.