Accumulator pre-charge pressure and required volume - critical for surge suppression in deck-machinery hydraulic systems.
Formula
$$ V_0 = \frac{\Delta V}{\left(\frac{p_0}{p_1}\right)^{1/n} - \left(\frac{p_0}{p_2}\right)^{1/n}} $$
Symbol legend
| Symbol | Meaning | Unit | Source |
|---|---|---|---|
| $p_0$ | Gas pre-charge pressure | bar | maker guideline |
| $p_1, p_2$ | Min / max working pressure | bar | system design |
Sources
- Bosch Rexroth Accumulator Handbook.