ShipCalculators.com

ASTM 54B Volume Correction Factor

Contents

Live calculator

VCF for generalised petroleum products (table 54B) - converts bunker volume at observed temperature to volume at 15 °C.

Formula

$$ VCF = e^{-\alpha \cdot (T - 15) \cdot (1 + 0.8 \alpha (T - 15))}, \; \alpha = \frac{192.4571}{\rho^2} + \frac{0.2438}{\rho} $$

Symbol legend

SymbolMeaningUnitSource
$\rho_{15}$Density at 15 °Ckg/m³BDN
$T$Observed temperature°Cthermometer
$α$Thermal expansion coefficient1/°Ctable 54B coefficient
$VCF$Volume correction factor-result

Sources

  • ASTM D1250 / API MPMS Ch.11.1.

See also