P/V valve setting check vs tank design pressure - positive and vacuum side.
Formula
$$ p_{set} \leq 1.1 p_{design},\ v_{set} \geq -7,kPa $$
Symbol legend
| Symbol | Meaning | Unit | Source |
|---|---|---|---|
| $p_{set}$ | P/V positive setting | kPa | SOLAS II-2 Reg.11.6 |
| $v_{set}$ | P/V vacuum setting | kPa | tank design |
Sources
- SOLAS II-2 Reg. 11.6.