Inert-gas plant capacity required per SOLAS II-2 Reg. 4: 125 % of the maximum combined cargo-discharge rate for all tanks simultaneously.
Formula
$$ \dot V_{IG} = 1.25 \cdot \dot V_{disch,max} $$
Symbol legend
| Symbol | Meaning | Unit | Source |
|---|---|---|---|
| $\dot V_{disch}$ | Maximum simultaneous discharge rate | m³/h | pump curves |
Sources
- SOLAS II-2 Reg. 4.5.5.
- OCIMF ISGOTT 6th Ed..