ShipCalculators.com

Inert-Gas Plant - Required Capacity

Contents

Live calculator

Inert-gas plant capacity required per SOLAS II-2 Reg. 4: 125 % of the maximum combined cargo-discharge rate for all tanks simultaneously.

Formula

$$ \dot V_{IG} = 1.25 \cdot \dot V_{disch,max} $$

Symbol legend

SymbolMeaningUnitSource
$\dot V_{disch}$Maximum simultaneous discharge ratem³/hpump curves

Sources

  • SOLAS II-2 Reg. 4.5.5.
  • OCIMF ISGOTT 6th Ed..