Flame arrester quench-gap size vs maximum experimental safe gap (MESG) - prevents flash-back from ignited vapours.

Formula

$$ gap \leq MESG $$

Symbol legend

SymbolMeaningUnitSource
$MESG$Maximum Experimental Safe GapmmIEC 60079-1

Sources