Waste-Heat Recovery Credit
Power generated by an exhaust-gas economiser and steam turbine, and the main-engine fuel it displaces. Feeds directly into EEDI innovative-tech credit (Category B) and FuelEU savings.
Main engine exhaust
WHR plant
Credit basis
WHR electric output
360kW
Aux fuel displaced
453.60t
CO₂ avoided
1,454.24t
Formula, assumptions, and limits
Exhaust energy ≈ SFOC × LCV per kWh at the shaft, of which η_WHR is extracted as electricity. The credit method in EEDI guideline MEPC.1/Circ.815 treats WHR as Category B and subtracts the P_WHR × SFOC_aux × Cf term from the EEDI numerator.