HomeCalculatorsSea Water Cooling Pump Capacity

Sea Water Cooling Pump Capacity

Q = Q_cooling_duty / (ρ·cp·ΔT) - cooling-water pump sized to reject engine heat at design ΔT.

Shipboard Systems
Mass flow
119.0kg/s
Volumetric flow
418m³/h

Formula, assumptions, and limits

$$Q_\text{pump} = \frac{\dot Q}{c_p \Delta T \rho}$$

cp = 4.2 kJ/(kg·K), ρ = 1025 kg/m³ for sea water. Typical design ΔT 5 K. Heat rejection ≈ (jacket + aux + LO + CAC + condenser) ~ 20-25 % of ME rated power on two-strokes.

Symbol legend

SymbolMeaningUnitSource
$\dot Q$Heat rejection dutykWengine heat balance
$ΔT$Cooling water ΔTKdesign
$c_p$Sea-water specific heatkJ/(kg·K)4.2

Spotted an error in this calculation? . We acknowledge editorial corrections within two working days.