HomeCalculatorsKG Limit - Intact (from GM-required)

KG Limit - Intact (from GM-required)

Maximum allowable KG (fluid) for an intact condition given KM at the draft and the required minimum GM.

KGGMLoading
Maximum KG (solid)
10.840m

Formula, assumptions, and limits

$$KG_{max} = KM - GM_{req} - \sum \frac{F_{SM}}{\Delta}$$

Loading computer tabulates KG-limit vs mean draft. Update FSM every condition for partially filled tanks, including consumables.

Symbol legend

SymbolMeaningUnitSource
$KM$Height of metacentre above keelmhydrostatic tables
$GM_{req}$Required GMmIS Code / class
$F_{SM}$Free-surface momentt·mstability booklet