HomeCalculatorsEmergency Fire Pump - SOLAS Requirement

Emergency Fire Pump - SOLAS Requirement

Emergency fire-pump capacity per SOLAS II-2 Reg. 10 - independent of main switchboard, capable of providing two hydrants at regulation pressure.

Fire pumpSOLAS II-2Emergency
Min capacity
40m³/h
Requirement note
Emergency pump min 40 m³/h at 0.27 N/mm² (cargo); 0.32 (pax); 0.35 (tanker)

Formula, assumptions, and limits

$$\dot V \geq \dot V_{min}(\text{ship type})$$

Emergency pump located outside main engine room, own diesel driver + suction source, can deliver above minimum pressure to two hydrants simultaneously. Weekly test.

Symbol legend

SymbolMeaningUnitSource
$\dot V$Emergency fire-pump capacitym³/hSOLAS II-2 Reg.10.2.5

Spotted an error in this calculation? . We acknowledge editorial corrections within two working days.