HomeCalculatorsISO 10816 Vibration Severity Zone

ISO 10816 Vibration Severity Zone

Classify a measured RMS vibration velocity against ISO 10816-3 zones A/B/C/D for machinery condition.

MaintenanceVibration
Severity zone
C - unsatisfactory (short-term)
Formula, assumptions, and limits

ISO 10816-3 tables. Zone A = just commissioned; B = acceptable long-term; C = short-term only / plan maintenance; D = shutdown risk. Applies to 10–1000 Hz RMS velocity on machine casing / pedestal.

Symbol legend

SymbolMeaningUnitSource
Broadband RMS velocitymm/svibration monitor
Machine size per ISO 10816-3I–IVdesigner