HomeCalculatorsSOx Scrubber - NaOH Dosing Rate

SOx Scrubber - NaOH Dosing Rate

NaOH consumption rate for a closed-loop EGCS - dependent on fuel sulphur mass flow and stoichiometry.

EGCSScrubberMARPOL VI
S in fuel
1.000t/day
Pure NaOH needed
2.43t/day
NaOH solution (50 %)
4.85t/day
Formula, assumptions, and limits

Stoichiometry: 1 mol S + 2 mol NaOH → Na₂SO₄. Apply 10 % excess in practice. Closed-loop scrubbers also generate wash-water that must meet MEPC.184(59) discharge criteria.

Symbol legend

SymbolMeaningUnitSource
Sulphur mass flowt/dayFOC × S%
SO₂ removal efficiency - OEM data